Overheating, siphon or ventilation unit
Breakdown: the boiler is stopped
This code does not mean the same on every boiler: on a Calenta, Tzerra M or Quinta Pro (E:12), the heat exchanger has gone above its normal temperature and the safety thermostat (STB) has tripped; on a Gas 210 Eco Pro (E:12), the siphon protection has tripped because the pressure in the flue is too high or the air supply is obstructed; on an Avanta, Avanta Plus, Avanta Platinum Plus or Aquanta (E12), the check of the heat recovery ventilation unit connected to the boiler has failed. In every case the boiler locks out (on a Tzerra M, which has no display, the light on the button then flashes red); for safety, since on a Gas 210 Eco Pro this code can mean a blocked flue, do not reset it before our technician has been.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Smell of flue gases? Switch the boiler off, open the windows, leave the premises and call us.
- Do not reset the boiler: call us.
Does your boiler show E:12?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E:12
The meaning depends on the boiler: find yours below.
Failure
Heat Recovery Unit
Control error of the heat recovery ventilation unit
Heat exchanger temperature beyond the normal range (STB maximum thermostat)
Heat exchanger temperature beyond the normal range (STB safety thermostat)
Heat exchanger temperature beyond the normal range (STB high limit thermostat)
Siphon protection activated
The boilers that show this code
What our technician checks
- The sensor's wiring and fitting, replaced if needed (Calenta, Tzerra M, Quinta Pro)
- Circulation (direction, pump, valves), bleeding and water pressure (Calenta, Tzerra M, Quinta Pro)
- How clean the heat exchanger is, and the boiler type parameter (Calenta, Tzerra M, Quinta Pro)
- The siphon: filled and not blocked (Gas 210 Eco Pro)
- The flue, the air supply and the cascade flap (Gas 210 Eco Pro)
- Heat exchanger fouling and the wiring (Gas 210 Eco Pro)
- The connection of the ventilation unit, with parameter P23 (Avanta Plus, Avanta Platinum Plus)
- The ventilation unit's operation and its connecting cable (Avanta, Aquanta)