Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Remeha Fault code Remeha
24

Return warmer than flow

Breakdown: the boiler is stopped

The boiler measures return water that is warmer than the flow water, which should not happen: flow sensor badly fitted, flow and return sensors or connections swapped, pump fitted the wrong way round (or, on the W40-m and W60-m Eco, too little water flow). The boiler goes into lockout (the digits flash) and only restarts after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 24?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 24

The meaning depends on the boiler: find yours below.

24

return temp > flow temp

Breakdown: the boiler is stopped Quinta 25/30s 28/35c, Quinta 45/65, Quinta 85
24

Return temp. > flow temp.

Breakdown: the boiler is stopped Quinta 115
24

Sensor fault

Breakdown: the boiler is stopped W40/60-m Eco

The boilers that show this code

What our technician checks

  • How the flow sensor is fitted
  • The pump direction and the flow and return connections, which must not be swapped
  • W40-m and W60-m Eco: the flow and return sensors, which must not be swapped
  • W40-m and W60-m Eco: the water flow

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.