Temperature gap to the return too large
Blocking: it retries by itself
The temperature difference between the heated water and the water coming back from the heating (return) is too large: on the Gas 210 Eco Pro it is measured between the heat exchanger and the return, on the Gas 310/610 Eco Pro between the flow and the return. Most often too little water is flowing, sometimes a sensor is at fault: it is a blocking code, the boiler stops and starts again by itself once the cause is gone.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the system water pressure: at least 0.8 bar. Too low? Top up with water as your installer showed you.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show Su:5?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code Su:5
The meaning depends on the boiler: find yours below.
Temperature difference too large between the heat exchanger and the return temperature
Maximum difference between flow and return temperature exceeded
What our technician checks
- Water circulation: direction, pump and valves
- Bleeding air from the system (Gas 210 Eco Pro)
- The system water pressure
- Fouling of the heat exchanger
- The temperature sensors: deviations, operation and fitting