Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Remeha Fault code Remeha
E04.23

Internal control error

Breakdown: the boiler is stopped

The boiler control has detected an internal error: internal communication stop on the Calenta Ace-Matic, Tzerra Ace-Matic and Avanta Ace, internal lockout of the gas valve control on the Quinta 45-115, Quinta Ace and Gas 210, 220 and 320/620 Ace. The boiler locks out and stays off until it is restarted and reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E04.23?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E04.23

The meaning depends on the boiler: find yours below.

E.04.23

Internal communication lockout

Breakdown: the boiler is stopped Avanta Ace
E.04.23

Internal error

Breakdown: the boiler is stopped Gas 210 Ace, Gas 220 Ace, Gas 320/620 Ace, Quinta 45-115
E04.23

Internal communication lockout

Breakdown: the boiler is stopped Calenta Ace-Matic, Tzerra Ace-Matic
E04.23

Internal error

Breakdown: the boiler is stopped Calenta Ace, Quinta Ace, Tzerra Ace

What our technician checks

  • A restart: power off and on again, then a reset
  • The gas valve wiring and the gas valve
  • The circuit board or control unit, replaced if necessary

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.