Code de blocage 5

Green light five times: parameter error

Blocking: it retries by itself

On the Tzerra M, the status light on the button flashes green five times: the control reports a parameter or identification error, which calls for restoring the boiler parameters or replacing the gas/air unit or the PSU board (codes Su:0, Su:16 to Su:19, read by our technician with a service tool). It is a blocking code: the boiler starts again by itself once our technician has restored the parameters or replaced the part.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show Code de blocage 5?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code Code de blocage 5

The meaning depends on the boiler: find yours below.

Code de blocage 5

Setting or identification error

Blocking: it retries by itself Tzerra M

What our technician checks

  • Parameters dF and dU, to be set again, and restoring the parameters (Su:0, Su:19)
  • The gas/air unit, to be replaced (Su:16, Su:17)
  • The PSU circuit board, to be replaced (Su:18)