Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Remeha Fault code Remeha
Code de blocage 1

Green light once: temperature protection

Blocking: it retries by itself

On the Tzerra M, the status light on the button flashes green once: the boiler is blocked by its temperature protection, because the flow temperature is too high, rises too fast or is too far from the return temperature, most often because too little water is flowing (codes Su:1, Su:2, Su:7, read by our technician with a service tool). The boiler starts again by itself once the cause is gone.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check the system water pressure: at least 0.8 bar. Too low? Top up with water as your installer showed you.
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show Code de blocage 1?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code Code de blocage 1

The meaning depends on the boiler: find yours below.

Code de blocage 1

Thermal safety

Blocking: it retries by itself Tzerra M

What our technician checks

  • Water circulation: direction, pump and valves
  • The system water pressure
  • Fouling of the heat exchanger
  • Operation and fitting of the sensors
  • The reason for the heat demand (Su:1)

Related codes