Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Remeha Fault code Remeha
Code de blocage 3

Green light three times: flame lost

Blocking: it retries by itself

On the Tzerra M, the status light on the button flashes green three times: the burner flame went out during operation, as there is no ionisation current any more, the signal that a flame is present (code Su:22, read by our technician with a service tool). The boiler tries to start again by itself; after five flame losses, it locks out (red light, three times).

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the boiler's gas tap is open.
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show Code de blocage 3?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code Code de blocage 3

The meaning depends on the boiler: find yours below.

Code de blocage 3

Flame loss

Blocking: it retries by itself Tzerra M

What our technician checks

  • The gas tap and the gas supply pressure
  • Purging air from the gas line
  • Operation and setting of the gas valve
  • The air supply and the flue (blockage)
  • Flue gas being drawn back in (on Gas 210 Eco Pro: how the flue is fitted and whether the heat exchanger leaks)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.