False flame signal
Breakdown: the boiler is stopped
On a Calenta, Tzerra M, Quinta Pro or Gas 210 Eco Pro, the boiler measures an ionisation current, so a flame signal, when there should be no flame: a burner that keeps glowing, a gas valve that leaks or stays open, a faulty ignition transformer. The boiler locks out and stays off until the cause is removed and it is reset (on a Tzerra M, which has no display, the light on the button then flashes red).
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E:16?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E:16
The meaning depends on the boiler: find yours below.
Parasitic flame
Parasitic flame signal
Wrong flame signal
The boilers that show this code
What our technician checks
- The ignition and ionisation electrode, replaced if needed
- The gas valve: tightness and closing, replaced if needed
- The combustion setting (CO2, or O2 on the Tzerra M and Quinta Pro)
- The ignition transformer, replaced if faulty (Gas 210 Eco Pro)
- The gas/air unit, replaced if needed, and the mains voltage (Tzerra M)