Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Remeha Fault code Remeha
E:16

False flame signal

Breakdown: the boiler is stopped

On a Calenta, Tzerra M, Quinta Pro or Gas 210 Eco Pro, the boiler measures an ionisation current, so a flame signal, when there should be no flame: a burner that keeps glowing, a gas valve that leaks or stays open, a faulty ignition transformer. The boiler locks out and stays off until the cause is removed and it is reset (on a Tzerra M, which has no display, the light on the button then flashes red).

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E:16?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E:16

The meaning depends on the boiler: find yours below.

E:16

Parasitic flame

Breakdown: the boiler is stopped Calenta, Quinta Pro
E:16

Parasitic flame signal

Breakdown: the boiler is stopped Tzerra M
E:16

Wrong flame signal

Breakdown: the boiler is stopped Gas 210 Eco Pro

The boilers that show this code

What our technician checks

  • The ignition and ionisation electrode, replaced if needed
  • The gas valve: tightness and closing, replaced if needed
  • The combustion setting (CO2, or O2 on the Tzerra M and Quinta Pro)
  • The ignition transformer, replaced if faulty (Gas 210 Eco Pro)
  • The gas/air unit, replaced if needed, and the mains voltage (Tzerra M)

Related codes