Remeha Fault code Remeha
b08

Too little air flow during pre-purge

Blocking: it retries by itself

Before ignition, the fan is not moving enough air through the boiler, often because the air inlet or the flue outlet is blocked (siphon included), or because of the air pressure switch. It is a blocking message: the boiler tries again by itself, but after several attempts it locks out with code 08, and it must not be reset then.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Do not reset the boiler: call us.
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show b08?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code b08

The meaning depends on the boiler: find yours below.

b08

Insufficient air transport during pre-purge

Blocking: it retries by itself Gas 210 Eco
b08

Air transport too low during pre-purge

Blocking: it retries by itself Gas 310 Eco, Gas 610 Eco

What our technician checks

  • The air inlet and the flue outlet: blockage or fitting error
  • The condensate siphon
  • The air pressure switch and its connections
  • Gas 610 Eco: the non-return valve