Remeha Fault code Remeha
H.02.79

Device lost on the system bus

Blocking: it retries by itself

A device is missing from the system bus (S-Bus, the cable linking boilers in a cascade): the Quinta 45-115 reports a connected device that is absent, the Gas 220 Ace and Gas 320/620 Ace no device at all on that bus. On these boilers it is a blocking message: the boiler stops normal operation and starts again by itself once the cause is gone.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show H.02.79?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code H.02.79

The meaning depends on the boiler: find yours below.

H.02.79

S-Bus device lost

Blocking: it retries by itself Gas 220 Ace, Gas 320/620 Ace, Quinta 45-115

What our technician checks

  • The S-Bus wiring and connectors
  • How the connectors are fitted
  • The end connectors with resistor: present and properly connected
  • Whether the connected devices are switched on

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.