Remeha Fault code Remeha
Su:22

Flame lost during operation

Blocking: it retries by itself

The burner flame went out while the boiler was heating: the boiler no longer measures an ionisation current, the signal that a flame is present. On the Calenta, Tzerra M, Quinta Pro, Gas 210 Eco Pro and Gas 310/610 Eco Pro it is a blocking code: the boiler tries to start again by itself and, if the cause remains, ends up locking out (on the Tzerra M, the status light on the button flashes green three times).

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the boiler's gas tap is open.
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show Su:22?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code Su:22

The meaning depends on the boiler: find yours below.

Su:22

Flame lost during operation

Blocking: it retries by itself Calenta, Quinta Pro
Su:22

No flame during operation

Blocking: it retries by itself Gas 310/610 Eco Pro, Tzerra M
Su:22

Flame extinguished during operation

Blocking: it retries by itself Gas 210 Eco Pro

The boilers that show this code

What our technician checks

  • The gas tap and the gas supply pressure
  • Purging air from the gas line
  • Operation and setting of the gas valve
  • The air supply and the flue (blockage)
  • Flue gas being drawn back in (on Gas 210 Eco Pro: how the flue is fitted and whether the heat exchanger leaks)

Related codes