Return too hot or flow-return difference too large
Breakdown: the boiler is stopped
On the Calenta Ace, Tzerra Ace and Quinta Ace, the difference between the flow and return temperatures is too large: the water circulates poorly (air, pressure, pump, valves) or a sensor is badly connected or faulty; on the Calenta Ace-Matic and Tzerra Ace-Matic, the return sensor reads a temperature that is too high. On all these boilers it is a lockout: the boiler stops and only starts again once the cause has been removed and the boiler has been reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the system's water pressure: below 0.8 bar, top up with water as the user manual explains.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E00.07?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E00.07
The meaning depends on the boiler: find yours below.
Excessive return sensor temperature
Return dT too high
The return temperature difference is too large
What our technician checks
- Bleeding the air out of the system
- The system's water pressure
- Circulation: direction, heating pump and valves
- The boiler type parameter, where there is one
- Whether the heat exchanger is clean
- The sensor connections, up to the circuit board
- The sensors' operation, fitting and resistance
- The sensor, replaced if faulty