Flow temperature too high
Breakdown: the boiler is stopped
The water leaving the boiler for the heating has become too hot, usually because it is not circulating well: too little flow, air in the system or water pressure too low. The boiler goes into lockout (the digits flash) and only restarts after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Quinta 25s, 30s, 28c or 35c: look at the water pressure on the gauge under the boiler. Below 1.5 bar, top up the water with the boiler cold (below 40 °C), as your installer showed you.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 18?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 18
The meaning depends on the boiler: find yours below.
Temperature too high
Flow temperature too high
Max. water temp.
The boilers that show this code
What our technician checks
- The water flow through the boiler and the system
- Bleeding the air out of the system
- The flow and return sensors, their resistance measured
- The system water pressure (at least 0.8 bar)