Return too cold or fan fault
Breakdown: the boiler is stopped
This code does not mean the same on every boiler: on a Calenta, Tzerra M, Quinta Pro or Gas 210 Eco Pro (E:08), the return water temperature is too low, because of a badly connected or faulty sensor or water that is not circulating; on an Avanta, Avanta Plus, Avanta Platinum Plus or Aquanta (E08), the fan does not run, does not stop or shows a wrong speed. In both cases the boiler locks out and stays off until the cause is removed and it is reset (on a Tzerra M, which has no display, the light on the button then flashes red).
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- On a Calenta, Tzerra M or Quinta Pro: check the water pressure. Above 0.8 bar, bleed the radiators; below it, top up with water to about 1.5 bar as the user manual explains.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E:08?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E:08
The meaning depends on the boiler: find yours below.
Fan defective
Fan error
Return temperature too low
Return temperature below the normal range
The boilers that show this code
What our technician checks
- The return sensor's wiring and fitting, replaced if needed (E:08)
- Circulation (direction, pump, valves), bleeding and water pressure (E:08)
- How clean the heat exchanger is, and the boiler type parameter (E:08)
- The fan's operation and wiring (E08)
- The chimney draught (E08)