Remeha Fault code Remeha
A01.23

Poor combustion: flame lost while running

Blocking: it retries by itself

The boiler lost its flame while running, with no ionisation current, and reports it as poor combustion. It is a warning: the boiler keeps working, but the cause must be looked into.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the boiler's gas tap is open.
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show A01.23?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code A01.23

The meaning depends on the boiler: find yours below.

A.01.23

Incomplete combus.

Blocking: it retries by itself Quinta 45-115
A01.23

Poor combustion

Blocking: it retries by itself Calenta Ace
A01.23

Incompl. combustion

Blocking: it retries by itself Quinta Ace

What our technician checks

  • The gas tap, the gas supply pressure and purging the gas line
  • Gas valve operation and setting
  • The air supply and flue gas ducts (blockage)
  • Flue gas being drawn back in (recirculation)