Red light three times: ignition fault
Breakdown: the boiler is stopped
On the Tzerra M, the status light on the button flashes red three times: the boiler has locked out on an ignition fault, because of five failed burner starts, a false flame signal or five flame losses (codes E:14, E:16, E:36, read by our technician with a service tool). It no longer heats until the cause is removed and the boiler has been reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the boiler's gas tap is open.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show Code de défaut 3?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code Code de défaut 3
The meaning depends on the boiler: find yours below.
Ignition error
What our technician checks
- Wiring, short to earth and earthing
- The condition of the burner deck
- The gas tap, open, and the gas supply pressure
- Purging air from the gas line
- Operation and setting of the gas valve
- The air supply and the flue outlet (blockage)
- The ignition and ionisation electrode, and the ionisation current (at least 1 µA)
- False flame signal: the ionisation and ignition electrode, to be replaced
Related codes