Remeha Fault code Remeha
Code de défaut 3

Red light three times: ignition fault

Breakdown: the boiler is stopped

On the Tzerra M, the status light on the button flashes red three times: the boiler has locked out on an ignition fault, because of five failed burner starts, a false flame signal or five flame losses (codes E:14, E:16, E:36, read by our technician with a service tool). It no longer heats until the cause is removed and the boiler has been reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the boiler's gas tap is open.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show Code de défaut 3?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code Code de défaut 3

The meaning depends on the boiler: find yours below.

Code de défaut 3

Ignition error

Breakdown: the boiler is stopped Tzerra M

What our technician checks

  • Wiring, short to earth and earthing
  • The condition of the burner deck
  • The gas tap, open, and the gas supply pressure
  • Purging air from the gas line
  • Operation and setting of the gas valve
  • The air supply and the flue outlet (blockage)
  • The ignition and ionisation electrode, and the ionisation current (at least 1 µA)
  • False flame signal: the ionisation and ignition electrode, to be replaced