Five failed gas leak tests
Breakdown: the boiler is stopped
On the Gas 210 Eco Pro, the gas leak test (VPS), which checks the safety valves of the gas valve block at start-up, has failed five times in a row: a faulty gas valve, no or too little gas pressure, a wrongly set VPS switch, a wiring fault or a sensor. The boiler locks out: it only restarts once the cause is removed and the RESET button is pressed.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the boiler's gas tap is open.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E:15?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E:15
The meaning depends on the boiler: find yours below.
5 failed gas leak test attempts
What our technician checks
- The gas tap, open, and the gas inlet pressure
- Fitting and setting of the VPS switches
- The gas valve: leaking or staying open, replaced if needed
- The wiring, including swapped V1 and V2 plugs
- The sensor: fitting, replaced if needed