Heat exchanger temperature too high
Blocking: it retries by itself
The temperature of the boiler's heat exchanger has gone above its maximum operating value. On the Quinta 45-115, Gas 210 Ace, Gas 220 Ace and Gas 320/620 Ace it is a blocking message: the boiler stops normal operation and starts again by itself once the cause is gone.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the system water pressure: below 0.8 bar, top up with water as the user manual explains (recommended pressure 1.5 to 2.0 bar).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show H.01.13?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code H.01.13
The meaning depends on the boiler: find yours below.
TECHT > max
What our technician checks
- Water circulation: direction, pump and valves
- The system water pressure
- Operation of the sensors and how they are fitted
- How clean the heat exchanger is
- Whether the central heating has been properly bled of air