Fault codes De Dietrich

Type the code your boiler shows: what it means, what you can do, and when a technician is needed.

Sometimes a number follows the code (6A 227): type it too, the page shows what it means.

Your brand

Your boiler De Dietrich

The model is written on the rating plate, often under the cover.

All codes De Dietrich

A.00.00 Zone flow sensor open or missing
A.00.01 Zone flow sensor short-circuited
A.00.107 Lower tank sensor short-circuited
A.00.108 Lower tank sensor open or missing
A.00.109 Second flow sensor removed
A.00.110 Second flow sensor short-circuited
A.00.111 Second return sensor removed
A.00.112 Second return sensor short-circuited
A.00.113 Primary return sensor removed
A.00.114 Primary return sensor short-circuited
A.00.28 Solar temperature sensor disconnected
A.00.29 Solar temperature sensor short-circuited
A.00.30 Solar temperature sensor not detected
A.00.32 Outdoor sensor missing or open circuit
A.00.33 Outdoor sensor short-circuited
A.00.40 Water pressure low or not measured
A.00.41 Measured water pressure too high
A.00.42 Water pressure sensor not detected
A.00.57 Upper tank sensor open or missing
A.00.58 Upper tank sensor short-circuited
A.00.69 Buffer tank sensor disconnected
A.00.70 Buffer tank sensor short-circuited
A.00.74 Buffer tank sensor not detected
A.01.21 Hot water heating up too fast
A.01.23 Incomplete combustion in the boiler
A.02.06 Water pressure in the heating too low
A.02.33 Automatic filling takes too long
A.02.34 Automatic filling needed too often
A.02.36 A connected device no longer responds
A.02.37 Non-critical device disconnected
A.02.45 Connection problem on the communication bus
A.02.46 Error managing the connected devices
A.02.48 Configuration error of connected devices
A.02.49 Connected device initialisation failed
A.02.54 OpenTherm link warning
A.02.55 Serial number missing or invalid
A.02.69 Demonstration mode active
A.02.76 Custom settings memory full
A.02.80 Cascade controller or bus terminator missing
A.02.85 Hot water tank temperature too high
A.02.96 Anti-legionella cycle not completed
A.03.17 Safety check in progress
A.05.77 Combustion values outside the limits
A.05.79 Combustion values below the limits
A.05.90 Gas valve control restarted
A.05.93 Gas valve control outside the limits
A.08.02 Shower time elapsed
A.08.06 LIN pump 1 running under limited conditions
A.10.33 Upper hot water tank sensor open circuit
A.10.34 Upper hot water tank sensor short-circuited
A.10.45 Room sensor of circuit A missing
A.10.46 Room sensor of circuit B missing
A.10.47 Room sensor of circuit C missing
A.10.50 Upper hot water tank sensor missing
A.10.54 Hot water zone sensor missing
A.10.56 Hot water sensor of the AUX zone missing
A.21.01 Only one device detected on the S-Bus
A.21.02 Same device preferred and non-preferred
A.21.05 Too many devices detected on the S-Bus
A.21.06 S-Bus device list full
A00.34 Outdoor sensor expected but not detected
A00.81 Room temperature sensor not detected
A02.18 Boiler configuration error
A02.72 Boiler running in degraded mode
A05.29 Gas pressure below the limit
A05.30 Gas pressure check failed
A05.95 Brief interruption of the flame signal
B00 PSU circuit board wrongly configured
B01 Maximum flow temperature exceeded
B02 Flow temperature rising too fast
B03 Flame lost during operation
B04 Flue gas temperature too high
B07 Maximum flow-return difference exceeded
B08 RL input of the PCU board open
B09 Blocking message BL.INV. L/N
B10 BL input of the PCU board open
B11 BL input of the PCU board open
B12 Flue gas pressure switch open
B13 Communication error with the SCU board
B14 Water pressure too low
B15 Gas pressure too low or internal fault
B16 SU circuit board not recognised
B17 PCU board settings corrupted
B18 PSU circuit board not recognised
B19 Boiler not configured
B21 Communication error between PCU and SU boards
B22 Flame loss or burner settings
B23 Mains voltage too low
B25 SU board error or outdoor sensor
B26 Hot water tank sensor disconnected
B27 Plate heat exchanger outlet sensor
B28 HL tank detected but cannot be controlled
B34 Unknown blocking code: PCU configuration
D03 Circuit B flow sensor fault
D04 Circuit C flow sensor fault
D05 Outdoor sensor fault
D07 Auxiliary or system sensor fault
D09 Domestic hot water sensor fault
D11 Circuit A room sensor fault
D12 Circuit B room sensor fault
D13 Circuit C room sensor fault
D14 Link lost with the radio boiler module
D15 Buffer tank sensor fault
D16 Swimming pool sensor fault
D17 Tank 2 sensor fault
D18 Solar tank sensor fault
D19 Solar collector sensor fault
D20 Link lost with the solar controller
D27 Link lost between the SCU and PCU boards
D29 Link lost with valve module B
D30 Link lost with valve module C
D31 The IOBL function is no longer active
D32 Five resets in less than an hour
D37 Titan Active System anode short circuit
D38 Titan Active System anode disconnected
D99 SCU software does not recognise the PCU
DEF. S.AMB.A Circuit A room sensor open or shorted
DEF. S.AMB.B Circuit B room sensor open or shorted
DEF. S.AMB.C Circuit C room sensor open or shorted
DEF. S.DEP.A Circuit A flow sensor open or shorted
DEF. S.ECS Hot water sensor open or short-circuited
DEF. S.EXT. Outdoor sensor open or short-circuited
DEF.S.AUX.1 Auxiliary sensor 1 open or short-circuited
DEF.S.AUX.2 Auxiliary sensor 2 open or short-circuited
DEF.S.BAL. 2 Second tank sensor open or short-circuited
DEF.S.BAL.TP Buffer tank sensor open or short-circuited
DEF.S.CHAUD Boiler sensor open or short-circuited
DEF.S.DEP.B Circuit B flow sensor open or shorted
DEF.S.DEP.C Circuit C flow sensor open or shorted
DEF.S.FUMEE Flue gas sensor open or short-circuited
DEF.S.PISC.A Circuit A pool sensor open or shorted
DEF.S.PISC.B Circuit B pool sensor open or shorted
DEF.S.PISC.C Circuit C pool sensor open or shorted
DEF.S.PISCINE Pool sensor open or short-circuited
DEF.S.SOLAIRE Solar sensor open or short-circuited
DEF.S.UNIV Universal sensor open or short-circuited
DEFAUT S.AMB.A Circuit A room sensor open or shorted
DEFAUT S.AMB.B Circuit B room sensor open or shorted
DEFAUT S.AMB.C Circuit C room sensor open or shorted
DEFAUT S.DEP.B Circuit B flow sensor open or shorted
DEFAUT S.DEP.C Circuit C flow sensor open or shorted
DEFAUT S.ECS Hot water sensor open or short-circuited
DEFAUT S.EXT. Outdoor sensor open or short-circuited
DEFAUT S.FUMEE Flue gas sensor open or short-circuited
E.00.04 Return temperature sensor disconnected
E.00.05 Return temperature sensor short-circuited
E.00.08 Heat exchanger sensor missing or open
E.00.09 Heat exchanger sensor short-circuited
E.00.16 Hot water tank sensor missing or open
E.00.17 Hot water tank sensor short-circuited
E.00.18 Hot water tank sensor not detected
E.00.20 Flue gas temperature sensor missing or open
E.00.21 Flue gas temperature sensor short-circuited
E.01.04 Flame lost several times
E.01.11 Fan speed out of range
E.01.24 Too many combustion errors in 24 hours
E.02.04 Configuration parameter error
E.02.13 Boiler locked by an external device
E.02.16 Internal memory (CSU) error
E.02.17 Internal circuit board communication error
E.02.35 Critical safety device disconnected
E.02.47 Connection to a connected device failed
E.02.48 Function group configuration error
E.02.51 Gas valve control parameter error
E.02.52 Burner profile error (gas valve control)
E.02.70 Heat recovery unit test failed
E.02.90 Boiler room ventilation timed out
E.04.00 Safety parameters incorrect
E.04.01 Flow temperature sensor short-circuited
E.04.02 Flow temperature sensor disconnected
E.04.03 Maximum flow temperature exceeded
E.04.04 Flue gas temperature sensor short-circuited
E.04.05 Flue gas temperature sensor missing or open
E.04.07 Mismatch between the two flow sensors
E.04.08 Safety input open or overheating
E.04.09 Mismatch between the two flue gas sensors
E.04.10 The burner fails to light
E.04.11 Gas valve leak test failed
E.04.12 False flame detected
E.04.13 Boiler fan fault
E.04.15 Flue gas outlet blocked
E.04.17 Gas valve control fault
E.04.18 Flow temperature below the minimum
E.04.20 Air flow sensor deviation
E.04.21 Deviation between the two burner sensors
E.04.23 Internal error in the boiler control
E.04.250 Gas valve or gas valve relay fault
E.04.254 Unknown error or gas valve circuit
E.04.29 Maximum number of resets reached
E00.00 Flow sensor missing or open circuit
E00.01 Flow sensor short-circuited
E00.06 Return temperature sensor not detected
E00.07 Return too hot or flow-return difference too large
E00.40 Water pressure sensor missing or open
E00.41 Water pressure sensor short-circuited
E00.44 Domestic hot water sensor open or missing
E00.45 Domestic hot water sensor short-circuited
E00.97 Flow sensor 2 missing
E00.98 Flow sensor 2 short-circuited
E01.12 Return warmer than the flow
E01.17 No water circulation, boiler locked out
E01.20 Maximum flue gas temperature reached
E02.07 Water pressure too low
E02.15 Configuration memory (CSU) not responding
E02.28 Lockout: flue gas pressure too high
E02.29 Lockout: flue gas temperature too high
E02.32 Automatic filling takes too long
E02.39 Pressure too low after automatic filling
E02.41 Flue gas pressure switch present, check wiring
E02.42 Flue gas thermostat present, check wiring
E02.44 Flue gas pressure switch not activated
E02.75 Lockout by the second flue gas pressure switch
E02.77 Lockout by the second flue gas thermostat
E04.06 Flue gas temperature too high
E04.14 Burner combustion fault
E04.24 Gas type not recognised
E04.25 Flame lost during the safety time
E04.26 Burner ignition error
E04.27 Gas valve open with flame detected
E04.28 Gas valve feedback fault
E04.50 Gas valve fault
E04.54 Board error or gas valve control
E07.10 Burner memory error
E07.11 Burner safety parameter error
E07.12 Safety thermostat tripped
E07.13 Oil pressure sensor fault
E07.14 No flame when the burner starts
E07.15 Internal burner error
E07.16 Burner motor fault
E07.17 Oil preheating takes too long
E07.18 Stray flame detected at the burner
E07.19 Oil pressure out of limits
E07.20 Flame lost three times in a row
E07.24 No communication with the burner
E07.25 Burner 2 memory error
E07.26 Burner 2 safety parameter error
E07.27 Safety thermostat tripped
E07.28 Burner 2 oil pressure sensor fault
E07.29 No flame when burner 2 starts
E07.30 Internal error on burner 2
E07.31 Burner 2 motor fault
E07.32 Oil preheating too long on burner 2
E07.33 Stray flame detected at burner 2
E07.34 Oil pressure out of limits on burner 2
E07.35 Burner 2 flame lost three times
E07.39 No communication with burner 2
H.00.02 Flow sensor expected but not detected
H.00.04 Return temperature sensor missing
H.00.05 Return temperature sensor short-circuited
H.00.105 Hot water loop sensor missing or open
H.00.106 Hot water loop sensor short-circuited
H.00.107 Hot water cylinder bottom sensor short-circuited
H.00.108 Hot water cylinder bottom sensor missing
H.00.18 Hot water tank sensor not detected
H.00.28 Solar collector sensor missing or open
H.00.29 Solar collector sensor short-circuited
H.00.30 Solar sensor expected but not detected
H.00.36 Second return sensor open or missing
H.00.37 Second return sensor short-circuited
H.00.42 Water pressure sensor fault
H.00.69 Buffer tank sensor disconnected
H.00.70 Buffer tank sensor short-circuited
H.00.71 Upper buffer tank sensor open circuit
H.00.72 Upper buffer tank sensor short-circuited
H.00.74 Buffer tank sensor not detected
H.00.75 Upper buffer tank sensor not detected
H.00.76 Cascade flow sensor open circuit
H.00.77 Cascade flow sensor short-circuited
H.00.78 Cascade flow sensor not detected
H.00.79 Swimming pool flow sensor open circuit
H.00.81 Room sensor or thermostat not detected
H.01.00 Circuit board communication error
H.01.05 Flow and return temperature gap too large
H.01.06 Exchanger to flow temperature gap too large
H.01.07 Exchanger to return temperature gap too large
H.01.08 Temperature rising too fast when heating
H.01.09 Gas pressure too low (gas pressure switch)
H.01.13 Heat exchanger maximum temperature exceeded
H.01.14 Maximum flow temperature exceeded
H.01.15 Flue gas temperature too high
H.01.18 No water circulation detected
H.01.21 Temperature rising too fast in hot water mode
H.02.00 Boiler reset in progress
H.02.02 Waiting for the configuration numbers
H.02.03 Configuration numbers incorrect (CN1, CN2)
H.02.04 Circuit board parameter error
H.02.05 Configuration memory not matching the board
H.02.07 Water pressure too low in the heating
H.02.09 Partial block by an external contact
H.02.10 Complete block by an external contact
H.02.12 External release signal not received
H.02.15 External configuration memory (CSU) not responding
H.02.18 Object dictionary error (OBD)
H.02.36 Optional circuit board (SCB) disconnected
H.02.38 Auto-fill limit reached or no water hardness
H.02.40 Function not available
H.02.45 CAN bus connection table full
H.02.46 CAN bus device table full
H.02.50 Function group communication error
H.02.55 Serial number missing or invalid
H.02.61 Function not supported by zone A
H.02.62 Function not supported by zone B
H.02.63 Function not supported by circuit C
H.02.64 Function not supported by zone D
H.02.65 Function not supported by zone E
H.02.66 Anti-corrosion anode (TAS) not detected
H.02.67 Anti-corrosion anode (TAS) short-circuited
H.02.70 External heat recovery unit test failed
H.02.79 Device missing from the system bus
H.02.80 Cascade controller missing
H.02.84 Two functions set on the same connector
H.03.00 Safety parameters missing or incorrect
H.03.01 Internal circuit board communication error
H.03.02 Flame lost during operation
H.03.05 Internal block or supply voltage too low
H.03.07 No matching parameter set detected
H.03.17 Gas control fault or safety check
H.03.254 Unknown or undefined error
H.03.32 Fan speed out of range
H.03.33 Mains frequency out of specification
H.03.34 Implausible flow temperature
H.03.35 Implausible return temperature
H.03.36 Flow temperature rising too fast
H.03.37 Flow and return difference too high
H.03.38 Calibration stopped: temperature too high
H.03.39 Boiler calibration failed
H.03.40 Sitherm Pro safety value out of range
H.03.41 Difference between the two flow sensors too high
H.08.07 Pump operating fault
H.08.08 LIN pump 1 locked
H.08.09 Communication with the pump lost
H.10.00 Circuit A flow sensor disconnected
H.10.01 Circuit A flow sensor short-circuited
H.10.02 Circuit A hot water sensor disconnected
H.10.03 Circuit A hot water sensor short-circuited
H.10.04 Circuit A pool sensor disconnected
H.10.05 Circuit A pool sensor short-circuited
H.10.09 Circuit B flow sensor disconnected
H.10.10 Circuit B flow sensor short-circuited
H.10.11 Circuit B hot water sensor disconnected
H.10.12 Circuit B hot water sensor short-circuited
H.10.13 Circuit B pool sensor disconnected
H.10.14 Circuit B pool sensor short-circuited
H.10.18 Circuit C flow sensor disconnected
H.10.19 Circuit C flow sensor short-circuited
H.10.20 Circuit C hot water sensor disconnected
H.10.21 Circuit C hot water sensor short-circuited
H.10.22 Circuit C pool sensor disconnected
H.10.23 Circuit C pool sensor short-circuited
H.10.27 Hot water zone flow sensor disconnected
H.10.28 Hot water zone flow sensor short-circuited
H.10.29 Hot water zone sensor disconnected
H.10.30 Hot water zone sensor short-circuited
H.10.36 AUX zone flow sensor disconnected
H.10.37 AUX zone flow sensor short-circuited
H.10.38 AUX zone hot water sensor disconnected
H.10.39 AUX zone hot water sensor short-circuited
H.10.59 Zone C safety thermostat open
H.21.00 No device detected on the S-Bus
H.21.07 Devices not available for the cascade
H00.00 Flow temperature sensor missing
H00.01 Flow temperature sensor short-circuited
H00.06 Return sensor expected but not detected
H00.16 Hot water tank sensor open or missing
H00.17 Hot water tank sensor short-circuited
H00.32 Outdoor sensor missing or open circuit
H00.33 Outdoor sensor short-circuited
H00.80 Pool flow sensor short-circuited
H01.03 Unintended flame loss detected
H01.26 Gas pressure too high
H02.06 Warning: water pressure too low
H02.16 Internal electronics error (CSU)
H02.25 Hot water tank anode fault
H02.26 Flue gas pressure too high
H02.27 Flue gas temperature too high
H02.31 Automatic water filling required
H02.37 Communication lost with the optional board
H02.43 Flue gas switch not activated at start
H02.47 Function group connection failed
H02.48 Function group configuration error
H02.49 SCB board initialisation failed
H02.60 Selected function not supported by the zone
H02.73 Blocked by the second flue gas pressure switch
H02.74 Blocked by the second flue gas thermostat
H02.91 Heating blocked by the multifunction input
H02.92 Hot water blocked by the multifunction input
H02.93 Heating and hot water blocked by multifunction input
H03.08 False flame detected
H03.09 Electrical supply voltage too low
H03.26 Boiler calibration requested
H03.28 Synchronisation error (power supply)
H03.31 Flue gas outlet blocked
H03.45 Manual lambda adjustment disabled
H03.54 Flame loss or unknown error
H07.01 Burner fault, control box locked out
H07.21 Burner supply voltage below 180 V
H07.22 No communication with the burner
H07.23 Burner parameter out of limits
H07.36 Burner 2 supply voltage below 180 V
H07.37 No communication with burner 2
H07.38 Burner 2 parameter out of limits
H20.36 Manual calibration failed
H20.39 Initial calibration not done
H20.40 Gas type not configured
L00 PSU circuit board fault
L01 Safety parameters incorrect
L02 Flow sensor short circuit or overheating
L03 Flow sensor open circuit or oil sensor
L04 Boiler too cold or ignition failure
L05 Boiler too hot or burner control fault
L06 Return sensor short circuit or burner motor
L07 Return sensor open or oil preheating too long
L08 Return too cold or stray flame
L09 Return too hot or oil pressure
L10 Flow-return difference too small or SU fault
L11 Flow-return difference too large or SU fault
L12 Safety thermostat open or SU fault
L13 Internal fault of the burner control unit
L14 Five failed burner starts or SU fault
L16 Stray flame detected
L17 Gas valve problem
L250 Water pressure too low
L251 Water pressure sensor fault
L30 Flue switch opened 5 times in 24 hours
L31 Flue gas overheated 5 times in 24 hours
L32 Flow sensor short circuit
L33 Flow sensor open circuit
L34 Fan or return sensor fault
L35 Flow and return swapped or return sensor open
L36 Flame lost several times
L37 Link lost with the burner control (SU)
L38 Link lost between the PCU and SCU boards
L39 BL input opened briefly
L40 Heat recovery unit test error
M04 Boiler service due
M05 Boiler service A due
M06 Boiler service B due
M07 Boiler service C due
M08 Boiler service due
M20 Automatic air purge in progress
M23 Outdoor sensor to be replaced
M30 No communication with the master controller
M31 MODBUS network wrongly configured
PURGE Hot water exchanger purge in progress
REVISION Boiler service is due
TA-S COURT-CIR Titan Active System short-circuited
TA-S DEBRANCHE Titan Active System disconnected (open circuit)
TA-S HS Internal fault in the Titan Active System
VOIR CAD Override active on a remote control
e01 Fault: check the water pressure first
e02 Fault: check the water pressure first
e04 Fault: check the gas tap
e07 Fault: check the water pressure first
e09 Fault: check the water pressure first