De Dietrich Fault code De Dietrich
A.02.33

Automatic filling takes too long

Blocking: it retries by itself

The automatic filling device took longer than the maximum time to put water back into the system. It is a warning: the boiler keeps running normally, but our technician needs to find the cause, for example a leak or a main water tap that is not fully open.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the main water tap is fully open.
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show A.02.33?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code A.02.33

The meaning depends on the boiler: find yours below.

A.02.33

ARTS comm err

Blocking: it retries by itself AMC
A.02.33

Time-out of the communication with the automatic filling system

Blocking: it retries by itself Virtuens
A02.33

Maximum filling time exceeded error

Blocking: it retries by itself MPX2 Compact, Virtuens

What our technician checks

  • The main water tap and the filling tap
  • The boiler and the system, for leaks
  • The pressure switch wiring
  • The filling settings AP069 and AP070
  • The automatic filling device, replaced if its valve is faulty
  • The circuit board, replaced if needed

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.