Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
De Dietrich Fault code De Dietrich
A.02.06

Water pressure in the heating too low

Blocking: it retries by itself

The water pressure in the heating circuit has dropped too low, though not yet to a critical level. It is a warning on the C 230 Evo, AMC, AMC Pro Evo, MCR-S, MPX2 Compact, Virtuens and Modulens O AFC-S: the boiler keeps running, but if the pressure keeps falling it may stop.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check the water pressure shown: if it is below 0.8 bar, top up the system with water (recommended pressure: 1.5 to 2 bar, 1.0 to 2 bar on the MPX2 Compact).
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show A.02.06?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code A.02.06

The meaning depends on the boiler: find yours below.

A.02.06

Water pressure

Blocking: it retries by itself AMC, AMC Pro Evo, C 230 Evo
A.02.06

Low pressure in the heating circuit

Blocking: it retries by itself MCR-S
A.02.06

Water pressure warning active

Blocking: it retries by itself Virtuens
A02.06

Low pressure in the heating circuit

Blocking: it retries by itself MPX2 Compact, Virtuens
A02.06

Water pressure warning active

Blocking: it retries by itself Modulens O AFC-S

What our technician checks

  • The system pressure, to be restored
  • The expansion vessel pressure
  • The boiler and the system, for leaks

Related codes