Waiting for the configuration numbers
Blocking: it retries by itself
The boiler is waiting for its configuration numbers (CN1 and CN2), which tell it which model it is: they are missing, for example after the circuit board has been replaced (C 230 Evo, AMC, AMC Pro Evo, MCR-S, MPX2 Compact, Virtuens, Modulens O AFC-S, CFU, CFU C). It is a blocking fault: the boiler does not heat until our technician has entered these numbers, then it starts again by itself.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show H.02.02?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code H.02.02
The meaning depends on the boiler: find yours below.
Waiting config no.
Waiting for the configuration parameters to be entered (CN1,CN2)
Waiting for the configuration number
Waiting for the configuration parameters to be entered (CN1,CN2)
Waiting for the configuration number / Waiting config no.
Waiting config no.
What our technician checks
- The CN1 and CN2 numbers, to be entered from the rating plate
- Modulens O AFC-S: the burner parameters, after configuration