Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
De Dietrich Fault code De Dietrich
H.02.03

Configuration numbers incorrect (CN1, CN2)

Blocking: it retries by itself

The boiler's configuration numbers (CN1 and CN2) are incorrect or unknown, for example after the circuit board has been replaced (C 230 Evo, AMC, AMC Pro Evo, MCR-S, MPX2 Compact, Virtuens, Modulens O AFC-S, CFU, CFU C). It is a blocking fault: the boiler does not heat until our technician has entered the right numbers, then it starts again by itself.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show H.02.03?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code H.02.03

The meaning depends on the boiler: find yours below.

H.02.03

Config error

Blocking: it retries by itself AMC, AMC Pro Evo, C 230 Evo
H.02.03

Configuration parameters (CN1,CN2) entered incorrectly

Blocking: it retries by itself MCR-S
H.02.03

Configuration error

Blocking: it retries by itself Virtuens
H02.03

Configuration parameters (CN1,CN2) entered incorrectly

Blocking: it retries by itself MPX2 Compact, Virtuens
H02.03

Configuration error / Config error

Blocking: it retries by itself Modulens O AFC-S
H02.03

Config error

Blocking: it retries by itself CFU, CFU C

What our technician checks

  • The CN1 and CN2 numbers, to be entered from the rating plate
  • CFU and CFU C, after a board change: the automatic detection function
  • Modulens O AFC-S: the burner parameters, after configuration

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.