Maximum flow temperature exceeded
Blocking: it retries by itself
The water leaving the boiler for the heating has gone above its maximum operating temperature (C 230 Evo, AMC Pro Evo, Virtuens, Modulens O AFC-S); on the MCR-S, MPX2 Compact and Virtuens (CU-GH-21 board), the code also covers the water returning from the heating, and the manual puts it down to insufficient circulation. It is a blocking fault: the boiler stops and starts again by itself once the cause is gone.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the system water pressure: below 0.8 bar, top up with water as the user manual explains.
- Check that the radiator valves are open.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show H.01.14?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code H.01.14
The meaning depends on the boiler: find yours below.
T flow max
Maximum flow or return temperature value reached
The flow temperature has exceeded the maximum operating value
Maximum flow or return temperature value reached
The flow temperature has exceeded the maximum operating value
What our technician checks
- The flow sensor wiring and connectors
- Water circulation through the boiler and the system: direction, pump and valves
- The system water pressure
- Bleeding the air, with a manual bleed cycle
- How clean the heat exchanger is
- The flow and return sensors: operation and fitting