Temperature rising too fast when heating
Blocking: it retries by itself
When heating, the temperature rises faster than allowed, in the heat exchanger or in the flow to the heating, because the water is not flowing enough through the system or because of a sensor (C 230 Evo, AMC Pro Evo, MCR-S, MPX2 Compact, Virtuens, Modulens O AFC-S). It is a blocking fault: the boiler stops and starts again by itself once the cause is gone.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the system water pressure: below 0.8 bar, top up with water as the user manual explains.
- Check that the radiator valves are open.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show H.01.08?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code H.01.08
The meaning depends on the boiler: find yours below.
T gradient level 3
The flow temperature rises too quickly in heating mode
Maximum level 3 gradient exceeded in heating
The flow temperature rises too quickly in the heating installation
Delta T Max 3
What our technician checks
- Water circulation through the boiler and the system: direction, pump and valves
- The system water pressure
- Bleeding the air, with a manual bleed cycle
- MCR-S: pump operation
- How clean the heat exchanger is
- The temperature sensors: operation, connection and fitting