Five failed burner starts or SU fault
Breakdown: the boiler is stopped
On the Innovens MCA and Modulens G AGC the burner has failed to start 5 times: no ignition spark, a spark without a flame, or a flame that is poorly detected (ionisation current too low); on the Modulens O AFC LS (oil) the same code reports an internal fault of the burner control and safety unit (SU). It is a fault: the boiler stops and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- On an Innovens MCA or Modulens G AGC, check that the boiler's gas tap is open.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show L14?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code L14
The meaning depends on the boiler: find yours below.
DEF.ALLUMAGE
DEF.INTERNE SU
The boilers that show this code
What our technician checks
- The ignition spark (Innovens MCA, Modulens G AGC)
- The gas tap, when the spark gives no flame
- The ionisation current, at least 3 µA
- Modulens O AFC LS: the burner control and safety unit