De Dietrich Fault code De Dietrich
L14

Five failed burner starts or SU fault

Breakdown: the boiler is stopped

On the Innovens MCA and Modulens G AGC the burner has failed to start 5 times: no ignition spark, a spark without a flame, or a flame that is poorly detected (ionisation current too low); on the Modulens O AFC LS (oil) the same code reports an internal fault of the burner control and safety unit (SU). It is a fault: the boiler stops and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. On an Innovens MCA or Modulens G AGC, check that the boiler's gas tap is open.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show L14?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code L14

The meaning depends on the boiler: find yours below.

L14

DEF.ALLUMAGE

Breakdown: the boiler is stopped Innovens MCA, Modulens G AGC
L14

DEF.INTERNE SU

Breakdown: the boiler is stopped Modulens O AFC

The boilers that show this code

What our technician checks

  • The ignition spark (Innovens MCA, Modulens G AGC)
  • The gas tap, when the spark gives no flame
  • The ionisation current, at least 3 µA
  • Modulens O AFC LS: the burner control and safety unit