Return too hot or flow-return difference too large
Breakdown: the boiler is stopped
On the MPX2 Compact and Virtuens the return sensor measures an excessive temperature; on the AMC 24/28 BIC the difference between the flow and return temperatures is too large, for example because the water is not flowing enough or because of a sensor. On AMC 24/28 BIC, MPX2 Compact and Virtuens boilers it is a lockout: the boiler stops and only starts again once the cause has been removed and the boiler has been reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the system water pressure: if it is below 0.8 bar, top up with water.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E00.07?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E00.07
The meaning depends on the boiler: find yours below.
dT return too high
Excessive temperature of the return sensor
What our technician checks
- Bleeding the air out of the system (AMC 24/28 BIC)
- The system water pressure (AMC 24/28 BIC)
- Water circulation: direction, heating pump and valves (AMC 24/28 BIC)
- The boiler type parameter, if present (AMC 24/28 BIC)
- Fouling of the heat exchanger (AMC 24/28 BIC)
- How the sensors are connected and fitted
- The sensors' operation and resistance, measured with an ohmmeter, sensor replaced if needed