Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
De Dietrich Fault code De Dietrich
H.08.08

LIN pump 1 locked

Blocking: it retries by itself

The boiler's LIN 1 circulation pump reports a lock error in its operation; the manual puts it down to a faulty pump. On AMC Pro Evo and Virtuens boilers it is a blocking fault: the boiler interrupts its normal operation and starts again by itself once the cause has been removed.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show H.08.08?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code H.08.08

The meaning depends on the boiler: find yours below.

H.08.08

LIN pump 1 lockout

Blocking: it retries by itself AMC Pro Evo
H.08.08

LIN pump 1 operation lockout error

Blocking: it retries by itself Virtuens

What our technician checks

  • LIN pump 1, to be replaced if faulty

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.