Heat exchanger maximum temperature exceeded
Blocking: it retries by itself
The temperature of the heat exchanger, where the heating water is warmed, has gone above its maximum operating value, which can come from too little water flow, a sensor or a fouled heat exchanger (C 230 Evo, AMC, AMC Pro Evo, Virtuens). It is a blocking fault: the boiler stops and starts again by itself once the cause is gone.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the system water pressure: below 0.8 bar, top up with water as the user manual explains.
- Check that the radiator valves are open.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show H.01.13?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code H.01.13
The meaning depends on the boiler: find yours below.
T HEX > max
The heat exchanger temperature has exceeded the maximum operating value
What our technician checks
- Water circulation: direction, pump and valves
- The system water pressure
- Operation and fitting of the sensors
- How clean the heat exchanger is
- Bleeding the air from the system