Water pressure too low in the heating
Blocking: it retries by itself
The water pressure in the heating circuit is too low and water needs to be added. On the MCR-S, MPX2 Compact and Virtuens it is a temporary stop: the boiler stops and starts again by itself once the pressure is restored.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the system water pressure: below 0.8 bar, water must be added (recommended pressure 1.5 to 2 bar, 1.0 to 2 bar on the MPX2 Compact).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show H.02.07?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code H.02.07
The meaning depends on the boiler: find yours below.
Low pressure in the heating circuit (water top-up required)
Water pressure error active
Low pressure in the heating circuit (water top-up required)
What our technician checks
- The system pressure, brought back to the right value
- The expansion vessel pressure
- Leaks in the boiler and the system (MCR-S)
- The water pressure sensor (MPX2 Compact, Virtuens)
- A manual de-aeration cycle (MPX2 Compact, Virtuens)
- The pump and the water circulation (MPX2 Compact, Virtuens)
- The temperature sensors and their connection (MPX2 Compact, Virtuens)