Lockout by the second flue gas pressure switch
Breakdown: the boiler is stopped
The boiler has gone into fault because of the second flue gas pressure switch, after repeated blocking due to the flue gas pressure (5 times in 24 hours). On the Modulens O AFC-S it is a lockout: the boiler stops and only starts again after our technician has removed the cause and reset it.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Do not reset the boiler: call us.
- Can you smell flue gases? Switch the boiler off, open the windows, leave the premises and call us.
Does your boiler show E02.75?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E02.75
The meaning depends on the boiler: find yours below.
Device failed because of the second flue gas pressure switch
What our technician checks
- The pressure switch wiring
- The heat exchanger, cleaned, and the burner settings
- Condition of the flue, cleaned if necessary
- The condensate drain and the trap, cleaned
- The pressure switch, replaced if it has failed