Flame lost several times
Breakdown: the boiler is stopped
The burner has lost its flame several times while running: five times on the AMC, AMC Pro Evo and C 230 Evo, five times in 24 hours on the MCR-S, and after three H01.03 faults in the same heat demand on the CFU and CFU C oil boilers. On all these boilers it is a lockout: the boiler stops and only starts again once the cause has been removed and the boiler has been reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E.01.04?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E.01.04
The meaning depends on the boiler: find yours below.
Flame loss error
Flame loss detected five times in 24 hours
Flame loss error
What our technician checks
- The gas supply: line purged, gas valve open, supply pressure
- Setting and calibration of the gas valve
- The electrode: connection, wiring and condition
- The air supply and flue ducts, and flue gas recirculation
- How clean the heat exchanger is on the flue gas side
- The mains supply voltage
- CFU and CFU C: the oil circuit (air, oil valve open) and the flame detection cell