Boiler locked by an external device
Breakdown: the boiler is stopped
An external device connected to the boiler's blocking input (the BL contact, or X15 on the MCR-S) has stopped the boiler, or this input is wrongly set or badly wired; on the MCR-S the frost protection is off as well. On the AMC, AMC Pro Evo, C 230 Evo, MCR-S, Virtuens, Modulens O AFC-S, CFU and CFU C it is a lockout: the boiler stops and only starts again once the cause has been removed and the boiler has been reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E.02.13?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E.02.13
The meaning depends on the boiler: find yours below.
Blocking input
Complete boiler shutdown (frost protection function not active)
Blocking input of the control unit from an external appliance
Blocking input of the control unit from the external environment of the appliance
Blocking input
What our technician checks
- The external device connected to the blocking input (BL contact, X15) and the external cause
- The wiring and contact of the blocking input
- The parameter settings of this input (BL function, AP001)