Flame lost during operation
Blocking: it retries by itself
On the Modulens O AFC (oil), the burner flame disappeared during operation: the flame is no longer detected, or air has got into the oil circuit. It is a blocking message: the boiler stops and starts again by itself once the cause is gone.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show B03?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code B03
The meaning depends on the boiler: find yours below.