Maximum flow-return difference exceeded
Blocking: it retries by itself
The temperature difference between the water leaving for the heating and the water returning to the boiler has gone above its maximum, because the water is not flowing enough or because of a sensor. On the Innovens MCA and Modulens G AGC it is a blocking message: the boiler stops and starts again by itself once the cause is gone.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the radiator valves are open.
- Check the water pressure on the display: below 0.8 bar, top up with water as the user manual explains (recommended pressure 1.5 to 2.0 bar).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show B07?