The burner fails to light
Breakdown: the boiler is stopped
The burner has failed to light after several attempts (four on the MCR-S, five on the others): no spark, a spark but no flame, or a flame the boiler does not detect well enough. On the AMC, AMC Pro Evo, C 230 Evo, MCR-S, MPX2 Compact and Virtuens it is a lockout: the boiler stops and only starts again once the cause has been removed and the boiler has been reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E.04.10?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E.04.10
The meaning depends on the boiler: find yours below.
Ignition failure
The burner failed to light after 4 attempts
The burner failed to light after five attempts
What our technician checks
- The gas supply: line purged, gas valve open, supply pressure
- The gas valve: setting, calibration, operation and wiring
- The ignition and ionisation electrode, its wiring and condition
- The wiring between the CU-GH board and the ignition transformer
- The earthing
- The condition of the burner deck
- The fan and the air and flue ducts (blockages)
- The CU-GH board, replaced as a last resort