Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
De Dietrich Fault code De Dietrich
L05

Boiler too hot or burner control fault

Breakdown: the boiler is stopped

On the Innovens MCA and Modulens G AGC the boiler temperature is too high (STB DEPART), because of a sensor or water that is not circulating; on the Modulens O AFC the same code reports an internal fault of the burner control and safety unit (SU). It is a fault: the boiler stops and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. On an Innovens MCA or Modulens G AGC, check that the radiator valves are open, then bleed the air from the cold radiators, starting with the lowest floors.
  3. On an Innovens MCA or Modulens G AGC, check the water pressure on the display: below 0.8 bar, top up with water as the user manual explains (recommended pressure 1.5 to 2.0 bar).
  4. Reset the boiler once only.
  5. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show L05?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code L05

The meaning depends on the boiler: find yours below.

L05

STB DEPART

Breakdown: the boiler is stopped Innovens MCA, Modulens G AGC
L05

DEF.INTERNE SU

Breakdown: the boiler is stopped Modulens O AFC

The boilers that show this code

What our technician checks

  • The sensor connections
  • The sensor, replaced if faulty
  • Bleeding the air from the heating system
  • Water circulation: direction, pump and valves
  • The system water pressure
  • Modulens O AFC: the burner control and safety unit

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.