De Dietrich Fault code De Dietrich
E.04.07

Mismatch between the two flow sensors

Breakdown: the boiler is stopped

The two sensors that measure the temperature of the water leaving for the heating (the flow) give readings that are too far apart: a bad connection or a faulty sensor, or, on the MPX2 Compact and Virtuens, a badly placed sensor or too little water circulation. On the AMC, AMC Pro Evo, C 230 Evo, MPX2 Compact and Virtuens it is a lockout: the boiler stops and only starts again once the cause has been removed and the boiler has been reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E.04.07?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E.04.07

The meaning depends on the boiler: find yours below.

E.04.07

T flow sensor

Breakdown: the boiler is stopped AMC, AMC Pro Evo, C 230 Evo
E04.07

Maximum difference reached between the flow temperatures

Breakdown: the boiler is stopped MPX2 Compact, Virtuens

What our technician checks

  • The connection of the flow sensors
  • Position and operation of the sensors, replaced if faulty
  • MPX2 Compact, Virtuens: the system pressure and venting the air
  • MPX2 Compact, Virtuens: the pump and the water circulation

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.