Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
De Dietrich Fault code De Dietrich
H01.03

Unintended flame loss detected

Blocking: it retries by itself

The oil burner has lost its flame unintentionally, for example because of the oil supply, the cell that detects the flame or the burner settings. On the Modulens O AFC-S, CFU and CFU C it is a temporary stop: the boiler starts again by itself, but after 3 flame losses in the same heat demand the CFU and CFU C lock out (code E01.04).

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show H01.03?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code H01.03

The meaning depends on the boiler: find yours below.

H01.03

Warning: unintended flame loss detection

Blocking: it retries by itself Modulens O AFC-S
H01.03

Flame loss warn

Blocking: it retries by itself CFU, CFU C

What our technician checks

  • The oil tap, fully open
  • Leak-tightness of the oil circuit
  • The flame detection cell: condition and alignment with the combustion head mirror
  • How clean the combustion head mirror is
  • The burner settings and, on the AFC-S, the recirculation slot
  • The nozzle, replaced if necessary, and the burner combustion
  • CFU, CFU C: the safety thermostat, whether it has cut out
  • CFU, CFU C: the burner, following the burner fault list

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.