De Dietrich Fault code De Dietrich
E.04.08

Safety input open or overheating

Breakdown: the boiler is stopped

On the AMC, AMC Pro Evo and C 230 Evo the safety input has opened: the air pressure switch has seen too high a pressure in the flue (air or flue duct blocked, condensate trap blocked or empty, dirty heat exchanger); on the MCR-S the boiler has reached its maximum safety temperature (the water is not circulating well, or the safety thermostat is the cause). On all these boilers it is a lockout: the boiler stops and only starts again after our technician has removed the cause and reset it.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Do not reset the boiler: call us.

Does your boiler show E.04.08?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E.04.08

The meaning depends on the boiler: find yours below.

E.04.08

Safety input

Breakdown: the boiler is stopped AMC, AMC Pro Evo, C 230 Evo
E.04.08

Maximum safety temperature value reached

Breakdown: the boiler is stopped MCR-S

What our technician checks

  • The wiring and connectors of the air pressure switch
  • The non-return valve that does not open
  • The condensate trap, blocked or empty
  • The air supply and flue ducts, for blockages
  • How clean the heat exchanger is
  • MCR-S: pressure, venting, pump and circulation of the system
  • MCR-S: connection and operation of the safety thermostat

Related codes