Safety input open or overheating
Breakdown: the boiler is stopped
On the AMC, AMC Pro Evo and C 230 Evo the safety input has opened: the air pressure switch has seen too high a pressure in the flue (air or flue duct blocked, condensate trap blocked or empty, dirty heat exchanger); on the MCR-S the boiler has reached its maximum safety temperature (the water is not circulating well, or the safety thermostat is the cause). On all these boilers it is a lockout: the boiler stops and only starts again after our technician has removed the cause and reset it.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Do not reset the boiler: call us.
Does your boiler show E.04.08?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E.04.08
The meaning depends on the boiler: find yours below.
Safety input
Maximum safety temperature value reached
What our technician checks
- The wiring and connectors of the air pressure switch
- The non-return valve that does not open
- The condensate trap, blocked or empty
- The air supply and flue ducts, for blockages
- How clean the heat exchanger is
- MCR-S: pressure, venting, pump and circulation of the system
- MCR-S: connection and operation of the safety thermostat