Pressure too low after automatic filling
Breakdown: the boiler is stopped
During automatic filling the system water pressure has not risen enough (on the MCR-S: minimum pressure not reached after 6 minutes): for example a leak, a closed water tap or the filling device. On AMC 24/28 BIC, MCR-S, MPX2 Compact and Virtuens boilers it is a lockout: the boiler stops and only starts again once the cause has been removed and the boiler has been reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E02.39?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E02.39
The meaning depends on the boiler: find yours below.
AF low press rise
Minimum pressure not reached after 6 minutes of automatic filling
Insufficient pressure rise after an automatic filling
What our technician checks
- Leaks in the boiler and the system
- The system water pressure
- The main water tap and the filling tap, open
- Operation of the automatic filling
- The water pressure sensor and the pressure switch wiring
- The safety valve
- The circuit board, replaced if needed