Burner fault, control box locked out
Blocking: it retries by itself
The oil burner's control and safety box has locked out (red light on the box): the ignition, the flame or the oil supply is at fault. On the CFU and CFU C this code does not clear by itself: the boiler stays off until the burner is reset with the button on its safety box.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show H07.01?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code H07.01
The meaning depends on the boiler: find yours below.
Burner fault
What our technician checks
- The ignition transformer, the ignition electrodes, the high-voltage wiring and the earthing
- Alignment and condition of the flame detection cell
- Position and condition of the combustion head
- The oil supply: oil tap open, tank level, oil pump
- Tightness of the oil supply line (air in the circuit)
- The nozzle, which must not be blocked, and any flue gas recirculation
- CFU: the preheater, replaced if faulty (lockout after 400 seconds)
- The burner control and safety box, replaced if faulty