Flue gas pressure too high
Blocking: it retries by itself
The flue gas pressure switch has measured an extreme pressure in the flue gas outlet, for example because the flue gas path is partly or fully blocked, the heat exchanger is fouled or the condensate drain is blocked. On the Modulens O AFC-S and the CFU C it is a blocking fault: the boiler starts again by itself once the cause is gone, but if the code appears 5 times in 24 hours it locks out (code E02.28).
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Do not reset the boiler: call us.
- Can you smell flue gases? Switch the boiler off, open the windows, leave the premises and call us.
Does your boiler show H02.26?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code H02.26
The meaning depends on the boiler: find yours below.
The appliance is in Block state because of an extreme value of the flue gas pressure…
Flue gas P block
What our technician checks
- The wiring of the flue gas pressure switch
- Fouling of the heat exchanger, cleaned if necessary
- The burner settings and the combustion measurements
- Condition, leak-tightness and installation of the flue, cleaned if necessary
- The condensate drain and the trap, cleaned
- The flue gas pressure switch, replaced if it has failed