L11

Flow-return difference too large or SU fault

Breakdown: the boiler is stopped

On the Innovens MCA and Modulens G AGC the temperature difference between the water leaving for the heating and the water coming back is too large, because of a sensor or water that is not circulating; on the Modulens O AFC LS (oil) the same code reports an internal fault of the burner control and safety unit (SU). It is a fault: the boiler stops and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. On an Innovens MCA or Modulens G AGC, check that the radiator valves are open, then bleed the air from the cold radiators, starting with the lowest floors.
  3. On an Innovens MCA or Modulens G AGC, check the water pressure on the display: below 0.8 bar, top up with water as the user manual explains (recommended pressure 1.5 to 2.0 bar).
  4. Reset the boiler once only.
  5. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show L11?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code L11

The meaning depends on the boiler: find yours below.

L11

DT.DEP-RET>MAX

Breakdown: the boiler is stopped Innovens MCA, Modulens G AGC
L11

DEF.INTERNE SU

Breakdown: the boiler is stopped Modulens O AFC

The boilers that show this code

What our technician checks

  • The sensor connections
  • The sensor, replaced if faulty
  • Bleeding the air from the heating system
  • Water circulation: direction, pump and valves
  • The system water pressure
  • Modulens O AFC LS: the burner control and safety unit