H.01.05

Flow and return temperature gap too large

Blocking: it retries by itself

The difference between the temperature of the water going out to the heating and that of the water coming back has reached its maximum, for example because the water is not flowing enough through the system. It is a blocking fault: the boiler stops normal operation and starts again by itself once the cause is gone.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check the system water pressure: if it is below 0.8 bar, top up with water as the user manual explains.
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show H.01.05?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code H.01.05

The meaning depends on the boiler: find yours below.

H.01.05

Delta max TF-TR

Blocking: it retries by itself AMC, AMC Pro Evo
H.01.05

Maximum temperature difference between the flow temperature and the…

Blocking: it retries by itself MCR-S
H.01.05

Maximum difference between the flow temperature and the return temperature

Blocking: it retries by itself Virtuens
H01.05

Maximum temperature difference between the flow temperature and the…

Blocking: it retries by itself MPX2 Compact, Virtuens
H01.05

Max difference between the flow temperature and the return temperature

Blocking: it retries by itself Modulens O AFC-S

What our technician checks

  • Water circulation: direction, pumps and valves
  • The system water pressure
  • Bleeding the air from the heating circuit
  • How clean the heat exchanger is
  • Operation and fitting of the temperature sensors
  • The temperature sensor connections