Temperature rising too fast in hot water mode
Blocking: it retries by itself
While heating domestic hot water, the temperature of the water leaving the boiler rises too fast, for example because the water does not circulate enough or because of a temperature sensor error. On the AMC, AMC Pro Evo, MCR-S, MPX2 Compact, Virtuens and Modulens O AFC-S it is a blocking message: the boiler stops normal operation and starts again by itself once the cause is gone.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Look at the water pressure shown: below 0.8 bar the system is short of water and needs topping up; tell us when you call.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show H.01.21?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code H.01.21
The meaning depends on the boiler: find yours below.
Max.grad.3 DHW
Flow temperature rises too quickly during DHW production
Maximum level 3 temperature gradient in DHW
Flow temperature rises too quickly during DHW production
Maximum level 3 temperature gradient in DHW
What our technician checks
- Water circulation: direction, pump and valves
- Pump operation
- System water pressure
- A manual air purge
- Operation of the temperature sensors
- Sensor connections and fitting