E.01.24

Too many combustion errors in 24 hours

Breakdown: the boiler is stopped

The boiler has had several combustion errors within 24 hours: the burner flame is poorly detected (ionisation current too low), for example because of the gas supply, the gas valve setting or blocked air and flue ducts. On AMC and AMC Pro Evo boilers it is a lockout: the boiler stops and only starts again once the cause has been removed and the boiler has been reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E.01.24?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E.01.24

The meaning depends on the boiler: find yours below.

E.01.24

Combustion error

Breakdown: the boiler is stopped AMC, AMC Pro Evo

What our technician checks

  • Purging the gas line
  • The gas valve, fully open
  • The gas supply pressure
  • Operation and setting of the gas valve unit
  • The air supply and flue ducts, which must not be blocked
  • Any recirculation of flue gases