De Dietrich Fault code De Dietrich
H.10.30

Hot water zone sensor short-circuited

Blocking: it retries by itself

The temperature sensor of the hot water zone is short-circuited, because of a bad connection or a badly fitted or faulty sensor, or because a thermostat is connected in place of the sensor without the matching setting. On the AMC, AMC Pro Evo, Virtuens and Modulens O AFC-S it is a blocking message: the boiler stops normal operation and starts again by itself once the cause is gone.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show H.10.30?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code H.10.30

The meaning depends on the boiler: find yours below.

H.10.30

DHW zone sensor clsd

Blocking: it retries by itself AMC, AMC Pro Evo
H.10.30

Domestic hot water temperature sensor short-circuited

Blocking: it retries by itself Virtuens
H10.30

T DHW zone short-circ.

Blocking: it retries by itself Modulens O AFC-S

What our technician checks

  • Sensor wiring and connectors
  • How the sensor is fitted
  • The sensor, to be replaced if faulty
  • Parameter CP502, to be set to off if a thermostat replaces the sensor