Hot water zone sensor short-circuited
Blocking: it retries by itself
The temperature sensor of the hot water zone is short-circuited, because of a bad connection or a badly fitted or faulty sensor, or because a thermostat is connected in place of the sensor without the matching setting. On the AMC, AMC Pro Evo, Virtuens and Modulens O AFC-S it is a blocking message: the boiler stops normal operation and starts again by itself once the cause is gone.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show H.10.30?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code H.10.30
The meaning depends on the boiler: find yours below.
DHW zone sensor clsd
Domestic hot water temperature sensor short-circuited
T DHW zone short-circ.
What our technician checks
- Sensor wiring and connectors
- How the sensor is fitted
- The sensor, to be replaced if faulty
- Parameter CP502, to be set to off if a thermostat replaces the sensor