De Dietrich Fault code De Dietrich
E00.41

Water pressure sensor short-circuited

Breakdown: the boiler is stopped

The sensor that measures the heating water pressure is short-circuited or reads a pressure above its range, because of a wiring problem, a badly fitted sensor or a faulty sensor. On the AMC, C 230 Evo, MPX2 Compact, Virtuens and Modulens O AFC-S it is a lockout: the boiler stops and only starts again once the cause has been removed and the boiler has been reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E00.41?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E00.41

The meaning depends on the boiler: find yours below.

E.00.41

P water closed

Breakdown: the boiler is stopped AMC, C 230 Evo
E00.41

Water pressure sensor input closed

Breakdown: the boiler is stopped MPX2 Compact, Virtuens
E00.41

The water pressure sensor is short-circuited or a pressure above the range is…

Breakdown: the boiler is stopped Modulens O AFC-S

What our technician checks

  • The wiring and connectors of the pressure sensor
  • How the sensor is fitted, replaced if it is faulty
  • The system pressure and the expansion vessel pressure
  • Leak-tightness of the boiler and the system