De Dietrich Fault code De Dietrich
H02.73

Blocked by the second flue gas pressure switch

Blocking: it retries by itself

The second flue gas pressure switch has put the boiler into a blocking state, for example because the flue or the heat exchanger is fouled or the condensate drain is blocked. On the Modulens O AFC-S it is a blocking fault: the boiler starts again by itself once the cause is gone, but if the message comes back 5 times in 24 hours it locks out.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Do not reset the boiler: call us.
  3. Can you smell flue gases? Switch the boiler off, open the windows, leave the premises and call us.

Does your boiler show H02.73?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code H02.73

The meaning depends on the boiler: find yours below.

H02.73

Device blocked because of the second flue gas pressure switch

Blocking: it retries by itself Modulens O AFC-S

What our technician checks

  • The pressure switch wiring
  • The heat exchanger, cleaned, and the burner settings
  • Condition of the flue, cleaned if necessary
  • The condensate drain and the trap, cleaned
  • The pressure switch, replaced if it has failed