Blocked by the second flue gas pressure switch
Blocking: it retries by itself
The second flue gas pressure switch has put the boiler into a blocking state, for example because the flue or the heat exchanger is fouled or the condensate drain is blocked. On the Modulens O AFC-S it is a blocking fault: the boiler starts again by itself once the cause is gone, but if the message comes back 5 times in 24 hours it locks out.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Do not reset the boiler: call us.
- Can you smell flue gases? Switch the boiler off, open the windows, leave the premises and call us.
Does your boiler show H02.73?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code H02.73
The meaning depends on the boiler: find yours below.
Device blocked because of the second flue gas pressure switch
What our technician checks
- The pressure switch wiring
- The heat exchanger, cleaned, and the burner settings
- Condition of the flue, cleaned if necessary
- The condensate drain and the trap, cleaned
- The pressure switch, replaced if it has failed